220 MVA 230/34.5 kV ABB/Hitachi Transformer
- Rating
- 220 MVA
- Voltage
- 230/34.5 kV
- Quantity
- 1 unit
- Evidence
- Manufacturer and ratings supplied by J&J Transformers LLC
Listing reviewed
Email for Specs, Price & AvailabilityTransformer types and project fit
J&J Transformers LLC is a power transformer supplier serving utilities, data centers, EPCs and industrial projects nationwide. Browse GSU, substation, step-down and pad-mounted transformers by voltage and capacity. Need another configuration? Send Tommy Marco your kVA or MVA, voltages, quantity and required date. Each offered unit requires engineering review and written availability confirmation; subject to prior sale.
J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide
Tommy Marco · tommy@jjtransformers.com
Current transformer listings
Start with the public ratings below. Call or email Tommy for current availability, pricing, photos and the technical package. Each unit needs project-specific engineering review and remains subject to prior sale.
Listing reviewed
Email for Specs, Price & AvailabilityListing reviewed
Email for Specs, Price & AvailabilityListing reviewed
Email for Specs, Price & AvailabilityListing reviewed
Email for Specs, Price & AvailabilityJ&J supplies and sources large power transformers for U.S. projects. Start with a current listing or call Tommy with a requirement beyond the public inventory. GSU, substation, step-down and pad-mounted equipment follow different project specifications.
| Transformer class | Primary duty | Decision inputs | Next page |
|---|---|---|---|
| Generator step-up (GSU) | Raises generator terminal voltage to a plant or interconnection bus | Generator MVA, voltage, PF/reactive range, high-side voltage, impedance, BIL, GCB arrangement | GSU transformer page |
| Substation / power | Changes voltage between transmission, subtransmission, or campus distribution levels | MVA, HV/LV/tertiary, LTC/DETC, BIL, impedance, losses, cooling, fault duty | Substation transformer page |
| Pad-mounted | Outdoor compartmental distribution close to a load block | kVA, primary/secondary, loop/radial, dead/live front, fusing, switch, fluid, enclosure | Pad-mounted transformer page |
| Dry-type | Indoor or outdoor distribution where the chosen insulation system and enclosure fit the site | kVA/MVA, voltage, BIL, enclosure, ventilation, temperature rise, sound, harmonics, AHJ requirements | Transformer comparison guide |
A matching voltage ratio is the starting point. Compare the existing transformer and proposed replacement on the same rating basis before reserving equipment. Send the nameplate or one-line by email when available; an initial conversation can begin with MVA, voltages and your required date.
| Compare | What the project team needs to confirm |
|---|---|
| Capacity and cooling | Required MVA at each cooling stage, ambient conditions and operating duty—not only the highest rating. |
| Winding connections | High, low and tertiary voltages; vector group, phase displacement, neutral and grounding requirements. |
| System performance | Impedance with its MVA base, tap range and controls, insulation levels, protection and fault-duty requirements. |
| Installation and schedule | Terminal arrangement, dimensions, accessories, inspection, loading, transport and the needed-on-site date. |
Start with capacity, phase, frequency, high- and low-side voltages, duty, site, and needed-on-site date. To confirm a technical match, we may also need BIL, impedance, cooling, vector group, neutral and taps, fluid, losses, harmonics, site conditions, sound limits, and shipping constraints.
Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.
Yes. Email the required MVA or kVA, high- and low-side voltages, quantity and needed-on-site date. J&J reviews additional sourcing options for the requirement. Supply capability does not establish that a particular configuration is in stock.
No. The high-side voltage class does not identify the low-side or tertiary voltage. Use the exact-ratio pages or the listing's full voltage description, then request the records for that unit.
Call Tommy Marco at 346-276-9540 or email tommy@jjtransformers.com. Specifications, reports, photos and pricing are shared directly after contact, according to the records available for the proposed unit. Availability remains subject to prior sale and written confirmation.
Choose by duty: GSU for generator export, substation/power transformer for network or campus voltage transformation, and pad-mounted for compartmental medium-voltage distribution near loads.
Start with kVA/MVA, high and low voltage, phase, frequency, duty, site, and date; provide BIL, impedance, cooling, vector group, taps, site conditions, and documents when known.
BIL supports insulation coordination. Impedance affects fault current, regulation, reactive behavior, protection, and parallel operation. Both must match the system studies and purchaser specification.